ZGS-12 Intelligent Wood-laminated Box-type Substation
General introduction of ZGS-12 Intelligent Wood-laminated Box-type Substation
Item:ZGS-12 Intelligent Wood-laminated Box-type Substation
①Low loss
②Fully sealed and insulated to ensure safety
③Can be used in ring network and terminal
④Small size and compact structure
⑤Reliable power supply
- Introduction
- Contact Now
Our ZGS-12 intelligent wood-laminated box-type substationis Compact structure, small size, only about 1/3-1/5 of the domestic European-style box transformer of the same capacity, greatly reducing the floor space; fully sealed and fully insulated structure, no need for insulation distance, reliable protection of personal safety; high voltage use load Switch-fuse combined electrical protection; high-voltage wiring can be used for both ring network and terminal, flexible power supply mode, high reliability; excellent transformer performance: low loss, low noise, low temperature rise; strong overload capacity, short circuit resistance, impact resistance Strong capability; to meet various low-voltage output requirements, you can choose according to the plan or design your own; the cable head has two types: 200A elbow cable connector and 600A T-shaped connector, and the elbow cable connector is suitable for cables with a cross-sectional area of 35-185mm² , The T-joint is suitable for cables with a cross-sectional area of 35-500mm². The material of the cable head is divided into copper core and aluminum core, both of which can be equipped with fully insulated zinc oxide arresters. The 200A elbow cable head can be plugged and unplugged with load, and can also play the role of isolation switch.
Model Description
ZGS:Prefabricated Substation (American)
▢:Design Number
12/0.4:Rated voltage
(▢):High voltage switchgear equipped with main switch
Do not F-load switch; F. R-load switch + fuse
▢:Operating motor for high voltage switchgear
Mechanism category T-playing mechanism; S-manual mechanism
▢:Transformer rated capacity (kVA)
Working Environment:
◆The altitude does not exceed 1000m;
◆Ambient temperature: -35C +40C;
◆Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;
◆Installation site: no fire, explosion hazard, chemical corrosive gas and well-ventilated place, The angle of inclination is not more than 30.
Note: When the above normal use conditions are exceeded, the user can negotiate with the company.
Main Technical Parameters
NO. | Parameter | Unit | Value |
1 | Rated voltage | kV | 10/0.4 (high pressure/low pressure) |
2 | Maximum working voltage | kV | 12 (high pressure side) |
3 | Rated frequency | Hz | 50 |
4 | Rated Capacity | kVA | 50-1600 |
5 | 1 minute power frequency withstand voltage | kV | 35 |
6 | Lightning impulse voltage | kV | 75 |
7 | Cooling method | Oil-immersed self-cooling | |
8 | High voltage backup fuse breaking current | kA | 50 |
9 | Plug-in fuse breaking current | kA | 25 |
10 | Ambient temperature | °C | -35~+40 |
11 | Coil allowable temperature rise | °C | 65 |
12 | No-load voltage regulation | ±5% or ±2×2.5% | |
13 | Noise level | db | 50 |
14 | Protection class | IP43 |
Product Real Shot
Thank you for your attention on Vouchivan ELECTRIC!
We offer Oil immersed transformers, Dry type transformers, Compact transformer substations, etc.Vouchivan Updated
-
Sep 20,2024
How should I choose between an oil-immersed transformer and a dry-type transformer? -
Sep 20,2024
What are the common outdoor substation technologies? -
Sep 20,2024
Causes and Considerations for Oil Leakage and Operating Temperature in Oil-Immersed Transformers