S13 Oil Immersed Type Transformer
General introduction of S13 Oil Immersed Type Transformer
Item:S13 Oil Immersed Type Transformer
①Vacuum filter filling of transformer oil
②Stable electrical performance
③High dynamic stability
④Good thermal stability
⑤High overload capacity
⑥Long service life
- Introduction
- Contact Now
S13 Oil Immersed Type Transformer is adopts a new insulation structure to improve the short-circuit resistance; the iron core is made of high-quality cold-rolled silicon steel sheets; high-voltage windings are made of high-quality oxygen-free copper wire as the material , and adopts multi-layer cylindrical structure; all sturdy parts adopt special anti-loosening treatment.
The product has the characteristics of high efficiency and low loss, can save a lot of power consumption and operating costs, and has significant social benefits. It is a popularized new technology product.
Our S13 Oil Immersed Type Transformer Structural features
The no-load loss of S13 is about 30% lower than that of S11 transformer, and the energy saving effect is remarkable.Strong environmental protection effect: The design magnetic flux density of S13 transformer is lower than that of S11, and the transformer noise is lower than S11. Its energy-saving and environmental protection effect is widely recognized.The comprehensive use cost is low. Stable operation and high safety performance.
Our S13 Oil Immersed Type Transformer rated capacity:
10kva 、25kva、 30kva、 35kva、 63kva、 80kva、 100kva 、125kva 、200kva、250kva、315kva、400kva、500kva、 630kva 、800kva、1000kva、1250kva、1600kva、2000kva、2500kva、3150kva and so on.
Model Description
S:Three phase
13:Performance lecel code
M:Fully sealed
▢:Rated Capacity(kVA)
▢:Voltage level(kV)
Working Environment:
S13 Oil Immersed Type Transformer Use environmental conditions
● Installation altitude: no more than 1000m above sea level
● Ambient temperature: -40℃~+40℃
Main Technical Parameters
Model | Rated capacity (KVA) | link group label | Voltage combination (KV) | Load loss | Load loss (w) | No-load current | Short circuit impedance (%) | |||
High pressure | Tap range | low pressure | (W) | Dy | Yy | |||||
S13-M-30 | 30 | Yyn0 or Dyn11 | 10 6.3 6 | ±5±2×2.5% | 0.4 | 80 | 630 | 600 | 2.3 | 4 |
S13-M-50 | 50 | 100 | 910 | 870 | 2 | |||||
S13-M-63 | 63 | 110 | 1090 | 1040 | 1.9 | |||||
S13-M-80 | 80 | 130 | 1310 | 1250 | 1.9 | |||||
S13-M-100 | 100 | 150 | 1580 | 1500 | 1.8 | |||||
S13-M-125 | 125 | 170 | 1890 | 1800 | 1.7 | |||||
S13-M-160 | 160 | 200 | 2310 | 2200 | 1.6 | |||||
S13-M-200 | 200 | 240 | 2730 | 2600 | 1.5 | |||||
S13-M-250 | 250 | 290 | 3200 | 3050 | 1.4 | |||||
S13-M-315 | 315 | 340 | 3830 | 3650 | 1.4 | |||||
S13-M-400 | 400 | 410 | 4520 | 4300 | 1.3 | |||||
S13-M-500 | 500 | 480 | 5410 | 5150 | 1.2 | |||||
S13-M-630 | 630 | 570 | 6200 | 6200 | 1.1 | 4.5 | ||||
S13-M-800 | 800 | 700 | 7500 | 7500 | 1 | |||||
S13-M-1000 | 1000 | 830 | 10300 | 10300 | 1 | |||||
S13-M-1250 | 1250 | 870 | 12000 | 12000 | 0.9 | |||||
S13-M-1600 | 1600 | 1170 | 14500 | 14500 | 0.8 | |||||
S13-M-2000 | 2000 | 1510 | 17800 | 17800 | 0.8 | According to customer needs | ||||
S13-M-2500 | 2500 | 1780 | 20700 | 20700 | 0.7 | |||||
S13-M-3150 | 3150 | 2100 | 24300 | 24300 | 0.7 |
Product Real Shot
FAQ:
Q1: What parameters do I need to provide when ordering?
A1: 1.Rated capacity(kva)
2.Wingding Material (Aluminum or Copper)
3.Primary Voltage/Secondary Voltage
Q2: What's your MOQ(minimum order quantity)?
A2:One Set.
Thank you for your attention on Vouchivan ELECTRIC!
We offer Oil immersed transformers, Dry type transformers, Compact transformer substations, etc.Vouchivan Updated
-
Sep 20,2024
How should I choose between an oil-immersed transformer and a dry-type transformer? -
Sep 20,2024
What are the common outdoor substation technologies? -
Sep 20,2024
Causes and Considerations for Oil Leakage and Operating Temperature in Oil-Immersed Transformers