2000 kVA 11 kV Epoxy Resin Cast Dry Type Transformer

General introduction of   2000 kVA 11 kV Epoxy Resin Cast Dry Type Transformer

This 2000 kVA epoxy resin cast dry type transformer was delivered to South Africa in 2021. The rated power of the dry type transformer is 2000 kVA, the primary voltage is 11 kV and secondary voltage is 0.4kV.

  • Introduction
  • Contact Now

Product Introduction

This 2000 kVA epoxy resin cast dry type transformer was delivered to South Africa in 2021.

 

The rated power of the dry type transformer is 2000 kVA with AN/AF cooling, the primary voltage is 11 kV with ±2*2.5% tapping range (NLTC), the secondary voltage is 0.4kV with delta star connection.

 

Cast resin technology provides excellent insulation and environmental protection, this together with the foil winding technology inside the resin offers the ultimate dry type transformer in terms of dielectric performance and short circuit withstand ability and ensures long term reliability for both distribution and special applications. cast resin transformers can be supplied with either aluminum or copper windings together with possibility of class F or class H insulation system, they can be designed to in-door or out-door installation with different enclosures.


We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!

 

Advantages

Fire resistant /Self-extinguishing(F1)

Environmental class(E2) and climatic class (C2)

From IP00-IP56 enclosure with AN, AF, ANAF or AFWF cooling

Maintenance free

Environmental friendly ,90% of material recyclable

 

Temperature control system

Built-in PT100 probes in 3 phase windings to detect the real-time temperature of windings and cycle display them in the digital screen.

Open circuit alarm and fault self-check alarm display and signal output.

3 stages automatically actions while the temperature reached to the set value, 1st stage the cooling fans start automatically, 2nd stage high temperature alarm,3rd stage over temperature trip.

Fans manual/auto control switch, timing start/stop, history data output.

4-20mA current output

RS485 Modbus communication protocol

Environment temperature measurement

Core temperature measurement

 

Scope of Supply

Product: resin cast dry type transformer

Voltage level: up to 35KV

Rating level: up to 20MVA

The transformer can be designed according to customer’s requirements

 

Technical Data Sheet

2000 KVA Dry Type Transformer specifications and data sheet

Delivered to

South Africa

Year

2021

Model

SCB10-2000kVA-11/0.4kV

Type

Resin cast dry type transformer

Standard

IEC60076

Rated Power

2000 kVA

Frequency

50 HZ

Phase

Three

Cooling Type

AN/AF

Primary Voltage

11 kV

Secondary Voltage

0.4 kV

Winding Material

Aluminum

Vector Group

Dyn11

Impedance

6%

Tap Changer

NLTC

Tapping Range

±2*2.5%

No Load Loss

3.2 KW

On Load Loss

15.5 KW

Accessories

Temperature controller, Cooling fans, Enclosure

Remarks

N/A

 

2000kVA-11/0.4kV Transformer Drawing

2000 kVA transformer diagram drawing and size.


2000KVA transformer drawing

2000kVA-11/0.4kV Transformer  Manufacturing Process

2000kVA-11/0.4kV Transformer Winding  

0.4kV Transformer Winding

 

2000kVA-11/0.4kV Transformer Enclosure

0.4kV Transformer Enclosure


Finished 2000kVA-11/0.4kV Transformer

11kV epoxy resin cast transformer



2000 kVA  dry type transformer


2000 kVA epoxy resin cast dry type transformer


dry type power transformer

The epoxy resin dry type transformer has the characteristics of good electrical performance, strong lightning impact resistance, strong short-circuit resistance, small size, and light weight. The temperature display controller can be installed to display and control the operating temperature of the transformer windings to ensure the normal service life of the transformer.

 

Transformer ready for ship

Transformer delivery


Why Insulation resistance of dry type transformer decreased

1.Reason analysis. Pouring type dry transformer winding is mostly made of resin pouring, conductor material is sealed in it, so the decrease of insulation resistance is mostly caused by moisture condensation on the surface of winding, dust accumulation or part of insulation material being affected by moisture.

2.Processing method Clean winding surface, surface moisture condensation with dry cloth wipe, natural air can be restored. It can be dried by heater and ventilated by fan. The neutral line (zero row) of the three-phase connection of dry-type transformer can be disconnected. The megohm meter is used to determine which phase the problem is in, and then the problem is carefully searched and processed.

 

FAQ

1. What standard do you follow?

IEC 60076 standard, and all other major international standard such as ANSI, CSA, UL, etc.

2. What package do you have for transformers?

Standard package with welded iron frame packed with ply wood boxes.

3. How long can I receive my transformers?

The shipping time from our port (shanghai or Ningbo) to your port is range from one week to one month, depend on the distance.


Send us your detail requirements, we have professional service team to answer you ASAP!

Thank you for your attention on Vouchivan ELECTRIC!

We offer Oil immersed transformers, Dry type transformers, Compact transformer substations, etc.