10 MVA 10000 KVA High Voltage Cast Coil Dry Type Power Transformer
General introduction of 10 MVA 10000 KVA High Voltage Cast Coil Dry Type Power Transformer
The 10 MVA dry type transformer was delivered to Montreal, Canada in 2011, the rated power of the transformer is 10000 KVA.
- Introduction
- Contact Now
Product Introduction
The 10 MVA dry type transformer was delivered to Montreal, Canada in 2011, the rated power of the transformer is 10000 KVA. It is a cast coil dry type transformer 24.94kv to 4.16kv, the high voltage of this dry type transformer is 24.94kv, the low voltage is 4.16kv. This high voltage dry type transformer is equipped with a no load tap changer, the tapping range is ±2*2.5% at primary side, the cooling is ANAF, our 10 MVA dry type transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.
We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!
Advantages
Fire resistant /Self-extinguishing(F1)
Environmental class(E2) and climatic class (C2)
From IP00-IP56 enclosure with AN, AF, ANAF or AFWF cooling
Maintenance free
Environmental friendly ,>90% of material recyclable
Temperature control system
Built-in PT100 probes in 3 phase windings to detect the real-time temperature of windings and cycle display them in the digital screen.
Open circuit alarm and fault self-check alarm display and signal output.
3 stages automatically actions while the temperature reached to the set value, 1st stage the cooling fans start automatically, 2nd stage high temperature alarm,3rd stage over temperature trip.
Fans manual/auto control switch, timing start/stop, history data output.
4-20mA current output
RS485 Modbus communication protocol
Environment temperature measurement
Core temperature measurement
Scope of Supply
Product: Dry Type Transformer
Rated Power: Up to 20 MVA
Primary Voltage: Up to 35 KV
The transformer can be designed according to customer’s requirements
Technical Data Sheet
10 MVA dry type transformer specifications and data sheet
Delivered to | Montreal, Canada |
Year | 2011 |
Model | SCB-10MVA-24.94/4.16KV |
Type | Dry Type Transformer |
Standard | CSA |
Rated Power | 10 MVA |
Frequency | 60 HZ |
Phase | Three |
Cooling Type | ANAF |
Primary Voltage | 24.94 KV |
Secondary Voltage | 4.16 KV |
Winding Material | Aluminum |
Vector Group | Dyn11 |
Impedance | 5% |
Tap Changer | NLTC |
Tapping Range | ±2*2.5% |
No Load Loss | 11.5KW |
On Load Loss | 48KW |
Accessories | Standard Configuration |
10 MVA 24.94/4.16KV Transformer Manufacturing Process
What are Dry-Type Transformers?
A dry-type transformer has no moving parts, it is a static device that uses environmentally friendly temperature insulation systems. Traditional liquid-type transformers rely on environmentally taxing materials like oil or fire resistant liquid dielectric. “Dry” refers to the fact the system is cooled through natural ventilation as opposed to using oil, silicone or a liquid to cool coils and the electrical core. This type of transformer is defined as “voltage changing,” which means air is cooled instead of cooling liquid. The case the transformer sits inside is ventilated so air can cool coils.
Finished 10 MVA 24.94/4.16KV Transformer
Advantages of Dry Type Transformer
1、Safety for people and property.
2、Maintenance and pollution-free solution.
3、Easy installation.
4、Side clearance is less.
5、Environmentally friendly.
6、Excellent capacity to support overloads.
7、Reduced cost on civil installation works and fire protection systems.
8、Excellent performance in case of seismic events.
9、No fire hazard.
10、Excellent resistance to short circuit currents.
11、Long lasting due to low thermal and dielectric heating.
12、Suited for damp and contaminated areas.
10 MVA Transformer Packing
FAQ
1. What standard do you follow?
IEC 60076 standard, and all other major international standard such as ANSI, CSA, UL, etc.
2. What package do you have for transformers?
Standard package with welded iron frame packed with ply wood boxes.
3. How long can I receive my transformers?
The shipping time from our port (shanghai or Ningbo) to your port is range from one week to one month, depend on the distance.
Thank you for your attention on Vouchivan ELECTRIC!
We offer Oil immersed transformers, Dry type transformers, Compact transformer substations, etc.Vouchivan Updated
-
Sep 20,2024
How should I choose between an oil-immersed transformer and a dry-type transformer? -
Sep 20,2024
What are the common outdoor substation technologies? -
Sep 20,2024
Causes and Considerations for Oil Leakage and Operating Temperature in Oil-Immersed Transformers