1600 KVA-11(6.6)/0.42 KV Step Down Dry Type Transformer
General introduction of 1600 KVA-11(6.6)/0.42 KV Step Down Dry Type Transformer
Two units 1600 kVA epoxy resin cast dry type transformers were delivered to South Africa in 2023 August.
- Introduction
- Contact Now
Product Introduction
Two units 1600 kVA epoxy resin cast dry type transformers were delivered to South Africa in 2023 August.
The rated power of the dry type transformer is 1600 kVA with AN/AF cooling, the primary have two voltages which are 11 and 6.6 kV with ±2*2.5% tapping range (NLTC), the secondary voltage is 0.42 kV, they formed a vector group of Yyn0 for 11kV and Dyn11 for 6.6kV. The HV and LV cables are top entry, an 800 * 400mm opening is provided on the top of the enclosure for HV cable incoming, an 400*400mm opening is provided on the top of enclosure for LV cable incoming. Which is sealed with temporary low-carbon steel plate. The shock proof rubber pad is installed at the top of the transformer, which has excellent isolation effect and can reduce the impact of live load and seismic force on the transformer. There are three surge arresters installed on the enclosure and connected to the each phase of HV terminal.
Cast resin technology provides excellent insulation and environmental protection, this together with the foil winding technology inside the resin offers the ultimate dry type transformer in terms of dielectric performance and short circuit withstand ability and ensures long term reliability for both distribution and special applications. cast resin transformers can be supplied with either aluminum or copper windings together with possibility of class F or class H insulation system, they can be designed to in-door or out-door installation with different enclosures.
We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!
Advantages
Fire resistant /Self-extinguishing(F1)
Environmental class(E2) and climatic class (C2)
From IP00-IP56 enclosure with AN, AF, ANAF or AFWF cooling
Maintenance free
Environmental friendly ,>90% of material recyclable
Temperature control system
Built-in PT100 probes in 3 phase windings to detect the real-time temperature of windings and cycle display them in the digital screen.
Open circuit alarm and fault self-check alarm display and signal output.
3 stages automatically actions while the temperature reached to the set value, 1st stage the cooling fans start automatically, 2nd stage high temperature alarm,3rd stage over temperature trip.
Fans manual/auto control switch, timing start/stop, history data output.
4-20mA current output
RS485 Modbus communication protocol
Environment temperature measurement
Core temperature measurement
Scope of Supply
Product: resin cast dry type transformer
Voltage level: up to 35KV
Rating level: up to 20MVA
The transformer can be designed according to customer’s requirements
Technical Data Sheet
1600 KVA Dry Type Transformer specifications and data sheet
Delivered to | South Africa |
Year | 2023 |
Model | SCB-1600kVA-11(6.6)/0.42kV |
Type | Resin cast dry type transformer |
Standard | IEC60076 |
Rated Power | 1600 kVA |
Frequency | 50 HZ |
Phase | Three |
Cooling Type | AN/AF |
Primary Voltage | 11(6.6) kV |
Secondary Voltage | 0.42 kV |
Winding Material | Aluminum |
Vector Group | Yyn0&Dyn11 |
Impedance | 6% or above |
Tap Changer | NLTC |
Tapping Range | ±2*2.5% |
No Load Loss | 2450 W |
On Load Loss | 13000 KW |
Accessories | Temperature controller, Cooling fans, Enclosure, Skids, lifting lugs & pulling eyes, surge arrester, UPS/VSDs/LED Lighting/Controls,Rubber supports for anti vibration |
Remarks | N/A |
1600kVA-11(6.6)/0.42kV Transformer Drawing
1600 kVA transformer diagram drawing and size.
1600kVA-11(6.6)/0.42kV Transformer Manufacturing Process
Transformer Winding:
1.Our windings are made of high quality copper.
2.Both High Voltage (HV) and Low Voltage (LV) windings are done using Coil Winding Machines. The Copper or Aluminum strips/wires used in winding are meticulously selected for its quality to give the best output. The Copper or Aluminum strips/wires are paper covered and acts as insulators.
Transformer Enclosure:
Finished 1600kVA-11(6.6)/0.42kV Transformer
The epoxy resin dry type transformer has the characteristics of good electrical performance, strong lightning impact resistance, strong short-circuit resistance, small size, and light weight. The temperature display controller can be installed to display and control the operating temperature of the transformer windings to ensure the normal service life of the transformer.
1600kVA-11(6.6)/0.42kV Transformer Accessories
This transformer equipped a temperature controller,three HV surge arrester,six fans and three HV tap changer protective cover.
The fountion of dry type transformer temperature controller:
The dry type transformer temperature controller is an essential component in maintaining the proper functioning of this critical piece of electrical equipment. It is responsible for regulating the temperature inside the transformer and ensuring that it remains within safe operating levels.The foundation of the dry type transformer temperature controller is based on advanced technology and innovative design. It is crafted with the most high-quality materials and undergoes rigorous testing to ensure that it can withstand the demanding conditions of the electrical environment.Thanks to this technology, the transformer temperature controller provides reliable and accurate readings, allowing operators to monitor the temperature of their transformers and adjust them as needed. This is essential to prevent excessive heating, which can damage the equipment and result in downtime and repairs.
In addition, the temperature controller is easy to use and can be customized to meet the specific needs of each transformer. Its intuitive interface allows operators to quickly access critical information and make necessary adjustments, ensuring that the machine runs smoothly and efficiently all the time.Overall, the dry type transformer temperature controller is an essential component in maintaining the safety and efficiency of transformers. Its innovative design and advanced technology allow for reliable and accurate temperature regulation, providing peace of mind to operators and ensuring that critical electrical equipment remains up and running.
Dry Type Transformer Advantages:
1. No Fire Hazard
2. Safety for people and property
3. Outage customer costs
4. Ecological and Environmentally Friendly
5. Maintenance & Pollution Free
6. Suited for damp and/or contaminated
7. Excellent resistance to short circuit effect
8. Excellent capacity to support overload
9. Excellent performance toward seismic phenome
10. Saving Costs give lower installation related costs
11. Easy Installation
FAQ
1. What standard do you follow?
IEC 60076 standard, and all other major international standard such as ANSI, CSA, UL, etc.
2. What package do you have for transformers?
Standard package with welded iron frame packed with ply wood boxes.
3. How long can I receive my transformers?
The shipping time from our port (shanghai or Ningbo) to your port is range from one week to one month, depend on the dist
Thank you for your attention on Vouchivan ELECTRIC!
We offer Oil immersed transformers, Dry type transformers, Compact transformer substations, etc.Vouchivan Updated
-
Sep 20,2024
How should I choose between an oil-immersed transformer and a dry-type transformer? -
Sep 20,2024
What are the common outdoor substation technologies? -
Sep 20,2024
Causes and Considerations for Oil Leakage and Operating Temperature in Oil-Immersed Transformers